+86 18924678741

level 2 ev charger

Power 11KW/22KW
Display 4.3 Inches Screen
Installation Column/Wall-Mounted Type
Equipment size L359*140*H510(mm)
Input voltage range AC240V±15%/AC380V±15%
Output current range 16 Amp/50 Amp/32 Amp
Output voltage range AC240V±15%/AC380V±15%
IP rating IP 55
Working Temp -25 to 55°C
protocol OCPP 1.6J Protocol (Optional)
Network selection Ethernet/3G/4G/WIFI (Optional)
Protect

Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc.

Get last price

Product Attributes

Hongjiali New Energy The Level 2 EV Charger is a user-friendly, space-saving EV charger suitable for all EV drivers. Providing superior fast charging to all electric vehicle drivers. Charging time from empty to full takes about 3-8 hours, and the specific charging time is determined by the car's battery system.

Our level 2 ev chargers are the ideal, all-purpose solutions for businesses that want to offer EV charging for customers, employees or residents.

Level 2 ev charger product parameter introduction:

Parameters

Requirements

General Requirements

EV Charger Type

AC

Charger Capacity

11KW

22KW

Equipment size

L359*140*H510(mm)

Product Model NO.

ENC-ACB/L011A

ENC-ACB/L022A

ANSI-ACB/L011A

Mounting

Wall-Mounted/Column Type

Input Requirements

AC Supply System

Single-Phase, 3 Wire AC system(ANSI)

Three-Phase, 5 Wire AC system(ENC)

Nominal Input Voltage

AC380V±15%(ENC)

AC380V±15%

AC240V±15%(ANSI)

Input Frequency

50±3Hz

Environmental Requirements

Ambient Temperature Range

-25 to 55°C

Ambient Humidity

5 to 95%

Storage Temperature

-40 to 70°C

Mechanical Requirements

IP Ratings

IP 55

Cooling

Natural Cooling

Output Requirements

Number of Outputs

1

Type of Each Output

AC380V±15%(ENC)

AC380V±15%

AC240V±15%(ANSI)

Single Output Max.Current

16 Amp/50 Amp

32 Amp

User Interface & Display Requirements

Display & Touch-Screen Size

4.3 Inches Screen

User Authentication

QR Code/RFID Card /Password Login

Metering Information

Consumption Units

Communication Requirements

Communication between EVSE and Central server

OCPP 1.6J Protocol (Optional)

Interface between Charger and CMS

Ethernet/3G/4G/WIFI (Optional)

Protection & Safety Requirements

Executive Standard

IEC 62196 2017, IEC 61851 2017, SAE J1772, etc.

Safety Parameters

Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage

Protection, Short Circuit, Over Temperature, etc.


Product Description

Level 2 EV Charger Features:

1Delicate appearance, simple operation, convenient installation;

2High effiffifficiency, reliable and stable performance;

3Friendly interaction interface, 4.3-inch/7 inch color screen(optional);

4Support multiple modes of charging, operation management and payment;

5Support Ethernet or wireless telecommunication;

6Support RFID Card/OCPP 1.6J (optional);

7Support GBT/Type-1/Type-2 connector(or Socket)(optional);

8Overload integrated Protection;

9Support online data upgrade.

Level 2 EV Charger Applicable Scenes:

They are suitable for occasions such as private villas, residential areas, commercial offiffiffice buildings,urban complex parking lots or urban public charging stations that can charge slowly for a long time; or applied for 4S stores of new energy vehicles, workshop debugging areas, road rescue of new energy vehicles and other occasions that require frequent change of charging station sites or temporary power supply.

Level 2 EV Charger Project Display:
7kw-217kw-187kw-41

Production Certification

7kw-22kw.jpg

FAQ

Q1: Are you trading company or manufacturer?

A: We are a professional electric car charger manufacturer and source factory.

Q2: what is the lead time?

A: Usually, 15-20 working days to produce.

Q3: Can we ask you to print our logo into chargers? Can the color of the plug and wire be customized according to our requirements?

A: Yes. We support OEM/ODM production.

Q4: How about your product quality? What should I do if something goes wrong?

A: First of all, we sell our products for many years, and we have a professional engineering team in this field. Moreover, our products have been strictly inspected and repeatedly tested before leaving the factory, and the good and good rate of the varieties has reached 99.98%. Finally, we have service providers in some areas, please contact us for more information

Q5: What is your quality control system?

A: Complete all incoming material inspection, process inspection, and final inspection; 30 test procedures will be done before the goods leave the factory, and charging test videos will be sent; products have CE, ROHS, FCC, UL, KC certification.

Q6: Can I install the EV charger by myself?

A: Yes, but we suggest the user contact a professional electrician for installation to avoid potential safety hazards.

Q7:Why my charging power is lower than the specification?e?

A: Because during the charging session, a few factors will influence the output. Here is some potential reason:

①The BMS(Battery management system) of the car controls the charging session.

②The Max allowed current was set and limited through your APP.

For more details, please query us at sales@hjlcharger.com

Q8: How much time is required to fully charge my car using this charger?

A: The charging speed is determined by three factors working in conjunction: the On Board Charging (OBC) System, the maximum current allowed by the charging cable, and the EVSE. As an illustration, if the EV's maximum allowed power is 30KW and the battery capacity is 60KWh, it would take approximately 2 hours to charge the battery fully.

Q9: What is dynamic load balancing and why do I need that?

A: Dynamic load balancing is a technique that distributes the electrical load across multiple charging stations based on real-time demand. This helps prevent the electrical grid's overload and ensures that each charging station receives appropriate power.

Dynamic load balancing technology can help distribute the available power among multiple EV chargers in real-time, optimizing available power and reducing the risk of overloading the grid. This can help prevent power outages and reduce the need for costly grid upgrades.

Additionally, dynamic load Balancing can help reduce charging times and improve the overall charging experience for EV drivers, making it a valuable feature for both residential and commercial charging applications.

Recommended Reading

Get In Touch With Us

Whenever you need us, we're here for you. --- Contact us for all your support needs, from technology, general queries to information support, etc. Our hotline numbers and e-mail are open 24hx7d for your needs.

Copyright © 2023.Shenzhen Hongjiali New Energy Co., Ltd All rights reserved. Site Map back to home