Electric car charging station 22kw ev charger refers to electric vehicle charging equipment with an output power of 22 kilowatts. It is divided into wall-mounted, column-mounted, and floor-standing types, which can adapt to different charging environments and needs.
Electric car charging station 22kw ev charger has the characteristics of fast charging, flexible installation, economical and practical, stable and safe, and intelligent management. It has a wide range of application prospects in the market and can be used for charging at home or in shopping malls, hotels, office buildings and other places.
Electric car charging station 22kw ev charger product technical parameters are as follows:
Parameters | Requirements |
General Requirements | |
EV Charger Type | AC |
Charger Capacity | 22KW |
Equipment size | L324*W161*H1430(mm) / L359*140*H510(mm) |
Product Model NO. | ENC-ACB/L022A |
Mounting | Wall-Mounted/Column Type |
Input Requirements | |
AC Supply System | Single-Phase, 3 Wire AC system(ANSI) |
Three-Phase, 5 Wire AC system(ENC) | |
Nominal Input Voltage | AC380V±15% |
Input Frequency | 50±3Hz |
Environmental Requirements | |
Ambient Temperature Range | -25 to 55°C |
Ambient Humidity | 5 to 95% |
Storage Temperature | -40 to 70°C |
Mechanical Requirements | |
IP Ratings | IP 55 |
Cooling | Natural Cooling |
Output Requirements | |
Number of Outputs | 1 |
Type of Each Output | AC380V±15% |
Single Output Max.Current | 32 Amp |
User Interface & Display Requirements | |
Display & Touch-Screen Size | 4.3 Inches Screen |
User Authentication | QR Code/RFID Card /Password Login |
Metering Information | Consumption Units |
Communication Requirements | |
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) |
Protection & Safety Requirements | |
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |