Get portfolio solutions including recommended products for various electric vehicle charging. Hongjiali New Energy provides fast and connected electric vehicle (EV) charging solutions.
Generally available at public locations, dealerships, and commercial fleet companies, DCFC chargers can range in output from 50 kW to 350 kW.
90 kW to 120 kW dc fast charging stations product parameters:
Parameters | Requirements | |
General Requirements | ||
EV Charger Type | DC | |
Charger Capacity | 90KW/100KW | 120KW |
Equipment size | L700*W450*H1680(mm) | |
Product Model NO. | ENC-DCL100B ANSI-DCL100B JIS-DCL100B | ENC-DCL120B ANSI-DCL120B JIS-DCL120B |
Mounting | Ground-Mounted | |
Input Requirements | ||
AC Supply System | Three-Phase, 5 Wire AC system | |
Nominal Input Voltage | AC380V±15% | |
Input Frequency | 45-65Hz | |
Environmental Requirements | ||
Ambient Temperature Range | -25 to 55°C | |
Ambient Humidity | 5 to 95% | |
Storage Temperature | -40 to 70°C | |
Mechanical Requirements | ||
IP Ratings | IP 54 | |
Cooling | Air-cooled | |
Output Requirements | ||
Number of Outputs | 2 | |
Type of Each Output | DC200-750V DC150-500V(JIS) | |
Single Output Max.Current | 200 Amp | |
Power Factor | ≥0.99(50% load above) | |
User Interface & Display Requirements | ||
Display & Touch-Screen Size | 7 Inches Touch Screen with Shell | |
User Authentication | QR Code/RFID Card /Password Login | |
Metering Information | Consumption Units | |
Communication Requirements | ||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | ||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772,CHAdeMO etc. | |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |