Ev charging piles convert electricity from the grid into a standard of electricity that can be used to charge electric vehicles. Fixed on the ground or wall, it provides AC power for electric vehicles with on-board chargers, and converts AC power into DC power to charge the vehicle's battery.
Affordable wholesale EV charging pile with worldwide shipping. Get great prices and fast delivery from our online consultation.
Ev charging piles mainly include DC charging piles and AC charging piles. AC charging piles are dedicated to charging small electric vehicles with on-board chargers. DC charging piles are the most common type of charging piles on the market, generally 50-150KW charging piles, and the mainstream type is 100-120KW charging piles.
The product parameters of 100-120KW charging pile are as follows:
Parameters | Requirements | |
General Requirements | ||
EV Charger Type | DC | |
Charger Capacity | 100KW | 120KW |
Equipment size | L700*W450*H1680(mm) | |
Product Model NO. | ENC-DCL100B | ENC-DCL120B |
ANSI-DCL100B | ANSI-DCL120B | |
JIS-DCL100B | JIS-DCL120B | |
Mounting | Ground-Mounted | |
Input Requirements | ||
AC Supply System | Three-Phase, 5 Wire AC system | |
Nominal Input Voltage | AC380V±15% | |
Input Frequency | 45-65Hz | |
Environmental Requirements | ||
Ambient Temperature Range | -25 to 55°C | |
Ambient Humidity | 5 to 95% | |
Storage Temperature | -40 to 70°C | |
Mechanical Requirements | ||
IP Ratings | IP 54 | |
Cooling | Air-cooled | |
Output Requirements | ||
Number of Outputs | 2 | |
Type of Each Output | DC200-750V / DC150-500V(JIS) | |
Single Output Max.Current | 200 Amp | |
Power Factor | ≥0.99(50% load above) | |
User Interface & Display Requirements | ||
Display & Touch-Screen Size | 7 Inches Touch Screen with Shell | |
User Authentication | QR Code/RFID Card /Password Login | |
Metering Information | Consumption Units | |
Communication Requirements | ||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | ||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772,CHAdeMO etc. | |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |