Install EV charger stations in your multi-residential building to provide EV charging for every resident and provide EV charger station solutions for 100% electrification of your residential parking lots. We work closely with you every step of the way to ensure your ev charger station is tailored to meet your unique needs and specifications. We are a premium brand that helps you choose the best charger for your electric vehicle. As the most professional ev charger station manufacturer and supplier in China, we are characterized by high-quality products and excellent services. Providing high-tech, reliable and long-lasting ev charger stations. Experience enhanced security, convenience and battery protection! Help attract customers and move your business into the future with our professional commercial ev charger stations.
Recommended 100kw 120kw ev charger station, its product parameters are as follows:
Parameters | Requirements | |
General Requirements | ||
EV Charger Type | DC | |
Charger Capacity | 90KW/100KW | 120KW |
Equipment size | L700*W450*H1680(mm) | |
Product Model NO. | ENC-DCL100B | ENC-DCL120B |
ANSI-DCL100B | ANSI-DCL120B | |
JIS-DCL100B | JIS-DCL120B | |
Mounting | Ground-Mounted | |
Input Requirements | ||
AC Supply System | Three-Phase, 5 Wire AC system | |
Nominal Input Voltage | AC380V±15% | |
Input Frequency | 45-65Hz | |
Environmental Requirements | ||
Ambient Temperature Range | -25 to 55°C | |
Ambient Humidity | 5 to 95% | |
Storage Temperature | -40 to 70°C | |
Mechanical Requirements | ||
IP Ratings | IP 54 | |
Cooling | Air-cooled | |
Output Requirements | ||
Number of Outputs | 2 | |
Type of Each Output | DC200-750V / DC150-500V(JIS) | |
Single Output Max.Current | 200 Amp | |
Power Factor | ≥0.99(50% load above) | |
User Interface & Display Requirements | ||
Display & Touch-Screen Size | 7 Inches Touch Screen with Shell | |
User Authentication | QR Code/RFID Card /Password Login | |
Metering Information | Consumption Units | |
Communication Requirements | ||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | ||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772,CHAdeMO etc. | |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |