The 180kw double gun quick charging pile is mainly used for DC fast charging of electric vehicles, with a total output power of 180kW, an output current of 250A, an input voltage of AC 380V±15%, a frequency of 45-65Hz, an output voltage range of DC200-1000V, a 7-inch touch screen with a human-machine interface, an electrical interface GBT/CCS2/CCS1/ChAdeMO (optional), and a cable length of 5m. It is mainly suitable for commercial purposes, such as parking lots, gas stations or charging stations.
The technical parameters of the 180kw double gun quick charging pile are as follows:
Parameters | Requirements |
General Requirements | |
EV Charger Type | DC |
Charger Capacity | 180kw |
Equipment size | L720*W401*H2000mm/L750*W750*H1920mm |
Product Model NO. | ENC-DCL180B |
ANSI-DCL180B | |
JIS-DCL180B | |
Mounting | Ground-Mounted |
Input Requirements | |
AC Supply System | Three-Phase, 5 Wire AC system |
Nominal Input Voltage | AC380V±15% |
Input Frequency | 45-65Hz |
Environmental Requirements | |
Ambient Temperature Range | -25 to 55°C |
Ambient Humidity | 5 to 95% |
Storage Temperature | -40 to 70°C |
Mechanical Requirements | |
IP Ratings | IP 54 |
Cooling | Air-cooled |
Output Requirements | |
Number of Outputs | 2 |
Type of Each Output | 200-1000VDC |
Single Output Max.Current | 200/250 Amp |
Power Factor | ≥0.99(50% load above) |
User Interface & Display Requirements | |
Display & Touch-Screen Size | 7 Inches Touch Screen with Shell |
User Authentication | QR Code/RFID Card /Password Login |
Metering Information | Consumption Units |
Communication Requirements | |
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) |
Protection & Safety Requirements | |
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772,CHAdeMO etc. |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |