The 60kw single-gun intelligent charging pile is suitable for electric vehicle charging, with multiple interface options such as CCS1, CCS2, Chademo, and GB/T, and a maximum output power of 60kw. The entire charging process is intelligently controlled, providing an output voltage range of 200~1000V, providing a complete electric vehicle charging solution, as well as a reliable DC fast charging station and powerful connection functions, suitable for the public, shopping malls, factories, fleets and other places.
The technical parameters of the 60kw single-gun smart charging pile are as follows:
Parameters | Requirements | ||
General Requirements | |||
EV Charger Type | DC | ||
Charger Capacity | 60KW | ||
Equipment size | L700*W450*H1680(mm) | ||
Product Model NO. | ENC-DCL060A/B | ANSI-DCL060A/B | JIS-DCL060A/B |
Mounting | Ground-Mounted | ||
Input Requirements | |||
AC Supply System | Three-Phase, 5 Wire AC system | ||
Nominal Input Voltage | AC380V±15% | ||
Input Frequency | 45-65Hz | ||
Environmental Requirements | |||
Ambient Temperature Range | -25 to 55°C | ||
Ambient Humidity | 5 to 95% | ||
Storage Temperature | -40 to 70°C | ||
Mechanical Requirements | |||
IP Ratings | IP 54 | ||
Cooling | Air-cooled | ||
Output Requirements | |||
Number of Outputs | 1 or 2 | ||
Type of Each Output | 200-1000VDC | ||
Single Output Max.Current | 200/250 Amp | ||
Power Factor | ≥0.99(50% load above) | ||
User Interface & Display Requirements | |||
Display & Touch-Screen Size | 7 Inches Touch Screen with Shell | ||
User Authentication | QR Code/RFID Card /Password Login | ||
Metering Information | Consumption Units | ||
Communication Requirements | |||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | ||
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | ||
Protection & Safety Requirements | |||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772,CHAdeMO etc. | ||
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |