Portable ev charger 125 amp 30KW DC Electric Vehicle Charging Station, 80A Portable Charger 20KW is suitable for outdoor charging of electric vehicles, suitable for all electric vehicle models.
The 125-amp portable ev charger is compact and lightweight, and can be moved to different charging locations as needed by the user. It is simple to operate and user-friendly. The modular design facilitates equipment expansion and maintenance and supports fully automatic charging mode.
The Portable EV Charger 125 Amp is an intelligent fast charger that integrates charging cabinet functions, charger, power distribution system, etc. Portable (commonly known as mobile), special purposes such as electric vehicle faults on the road and on-site demonstration of charger systems.
Portable EV Charger 66A 125 Amp 20KW 30KW DC Electric Vehicle Charging Station Product Parameters:
Parameters | Requirements | |
General Requirements | ||
EV Charger Type | DC | |
Charger Capacity | 20KW | 30KW |
Equipment size | L650*W280*H369(mm) | |
Product Model NO. | ENC-DCX020A | ENC-DCX030A |
ANSI-DCX020A | ANSI-DCX030A | |
JIS-DCX020A | JIS-DCX030A | |
Mounting | Portable | |
Input Requirements | ||
AC Supply System | Three-Phase, 5 Wire AC system | |
Nominal Input Voltage | AC380V±15% | |
Input Frequency | 45-65Hz | |
Environmental Requirements | ||
Ambient Temperature Range | -25 to 55°C | |
Ambient Humidity | 5 to 95% | |
Storage Temperature | -40 to 70°C | |
Mechanical Requirements | ||
IP Ratings | IP 54 | |
Cooling | Air-cooled | |
Output Requirements | ||
Number of Outputs | 1 | |
Type of Each Output | 200-1000VDC | |
Single Output Max.Current | 66 Amp | 125 Amp |
Power Factor | ≥0.99(50% load above) | |
User Interface & Display Requirements | ||
Display & Touch-Screen Size | 4.3 Inches Touch Screen with Shell | |
User Authentication | QR Code/ Password Login | |
Metering Information | Consumption Units | |
Communication Requirements | ||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | ||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772,CHAdeMO etc. | |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |