The wallbox 22kw 11kw type 2 smart charging station is an important device that provides a fast and convenient charging solution for electric vehicles. It has the characteristics of efficient charging, intelligent control, strong compatibility, safety and reliability, and easy installation. It is one of the important equipment in the field of electric vehicle charging. Suitable for indoor and outdoor environments, it can meet home and commercial needs.
The wallbox 22kw 11kw type 2 smart charging station has intelligent charging and flexible configuration, intelligent authentication, plug and play, intelligent load management, flexible and convenient. Connector commercial use with OCPP. Equipped with App/RFID/WIFI/Bluetooth.
The product parameters of the wallbox 22kw 11kw type 2 smart charging station are as follows:
Parameters | Requirements | |
General Requirements | ||
EV Charger Type | AC | |
Charger Capacity | 11KW | 22KW |
Equipment size | L359*140*H510(mm) | |
Product Model NO. | ENC-ACB/L011A | ENC-ACB/L022A |
ANSI-ACB/L011A | ||
Mounting | Wall-Mounted/Column Type | |
Input Requirements | ||
AC Supply System | Single-Phase, 3 Wire AC system(ANSI) | |
Three-Phase, 5 Wire AC system(ENC) | ||
Nominal Input Voltage | AC380V±15%(ENC) | AC380V±15% |
AC240V±15%(ANSI) | ||
Input Frequency | 50±3Hz | |
Environmental Requirements | ||
Ambient Temperature Range | -25 to 55°C | |
Ambient Humidity | 5 to 95% | |
Storage Temperature | -40 to 70°C | |
Mechanical Requirements | ||
IP Ratings | IP 55 | |
Cooling | Natural Cooling | |
Output Requirements | ||
Number of Outputs | 1 | |
Type of Each Output | AC380V±15%(ENC) | AC380V±15% |
AC240V±15%(ANSI) | ||
Single Output Max.Current | 16 Amp/50 Amp | 32 Amp |
User Interface & Display Requirements | ||
Display & Touch-Screen Size | 4.3 Inches Screen | |
User Authentication | QR Code/RFID Card /Password Login | |
Metering Information | Consumption Units | |
Communication Requirements | ||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | ||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. | |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |