2 7kw pile home electric vehicle charging station refers to a household charging pile equipped with two 7-kilowatt charging guns, which can charge two electric vehicles at the same time. It adopts AC charging method, suitable for various household electric vehicles, and provides convenient and efficient charging services for car owners.
2 7kw pile home electric vehicle charging station is suitable for scenes such as parking lots and gardens. It is mainly used for AC charging of electric vehicles. The power is 7KW, the output current is 32A, and the strict waterproof protection makes the 2 7kw pile-type household electric vehicle charging station suitable for various indoor and outdoor places.
The product technical parameters of 2 7kw pile home electric vehicle charging station are as follows:
Parameters | Requirements | |
General Requirements | ||
EV Charger Type | AC | |
Charger Capacity | 7KW | |
Equipment size | L293*W140*H418(mm) / L324*W161*H1430(mm) | |
Product Model NO. | ENC-ACB/L007A | ANSI-ACB/L007A |
Mounting | Wall-Mounted/Column Type | |
Input Requirements | ||
AC Supply System | Single-Phase, 3 Wire AC system | |
Nominal Input Voltage | AC220V±15%(ENC) | AC240V±15%(ANSI) |
Input Frequency | 50±3Hz | |
Environmental Requirements | ||
Ambient Temperature Range | -25 to 55°C | |
Ambient Humidity | 5 to 95% | |
Storage Temperature | -40 to 70°C | |
Mechanical Requirements | ||
IP Ratings | IP 55 | |
Cooling | Natural Cooling | |
Output Requirements | ||
Number of Outputs | 1 | |
Type of Each Output | AC220V±15%(ENC) | AC240V±15%(ANSI) |
Single Output Max.Current | 32 Amp | |
User Interface & Display Requirements | ||
Display & Touch-Screen Size | 4.3 Inches Screen | |
User Authentication | QR Code/RFID Card /Password Login | |
Metering Information | Consumption Units | |
Communication Requirements | ||
Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | ||
Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. | |
Safety Parameters | Over Current, Over Voltage, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |